Datasheet

Operating conditions
V
DD
= 3.3 V
Clocks
OSC8M used as main clock source, running undivided at 8 MHz.
CPU is running on Flash with '0' wait states, at 8 MHz.
PTC running at 4 MHz.
PTC configuration
Mutual-Capacitance mode.
One-touch channel.
System configuration
Standby Sleep mode enabled.
RTC running on OSCULP32K: Used to define the PTC scan rate through the event system.
Drift Calibration disabled: No interrupts, PTC scans are performed in Standby mode.
Drift Calibration enabled: RTC interrupts (wake-up) the CPU to perform PTC scans. PTC drift calibration
is performed every 1.5 sec.
SAM D21 Family
AEC-Q100 125°C Specifications
© 2018 Microchip Technology Inc.
Datasheet Complete