Datasheet
...........continued
Symbol Parameter Conditions Temp. Min. Typ. Max. Units
I
SbyBOD33
Current consumption in
Standby mode
Sampling mode 25°C - 0.132 0.38 μA
-40 to
125°C
- - 1.62
t
STARTUP
Start-up time - 1.2
(1)
- μs
Note: 1. These values are based on simulation. These values are not covered by test limits in
production or characterization.
Table 39-12. BOD33 Characteristics (Device Variant B, C, D and L)
Symbol Parameter Conditions Temp. Min. Typ. Max. Units
Step size, between
adjacent values in
BOD33.LEVEL
- 34 - mV
V
HYST
V
BOD+
- V
BOD-
Hysteresis ON 35 - 170 mV
t
DET
Detection time Time with V
DDANA
<
V
TH
necessary to generate
a
reset signal
- 0.9
(1)
- μs
I
BOD33
Current consumption Continuous mode 25°C - 25 48 μA
-40 to
125°C
- - 52
Sampling mode 25°C - 0.03 0.21
-40 to
125°C
-- - 2.91
I
SbyBOD33
Current consumption in
Standby mode
Sampling mode 25°C - 0.13 0.38 μA
-40 to
125°C
- - 1.7
t
STARTUP
Start-up time - 2.2
(1)
- μs
39.6.3 Analog-to-Digital (ADC) characteristics
Table 39-13. Operating Conditions (Device Variant A)
Symbol Parameter Conditions Min. Typ. Max. Units
VDDANA Power Supply
Voltage
T>105°C 3 - 3.6 V
RES Resolution 8 - 12 bits
f
CLK_ADC
ADC Clock frequency 30 - 2100 kHz
SAM D21 Family
Electrical Characteristics at 125°C
© 2018 Microchip Technology Inc.
Datasheet Complete
DS40001882D-page 1075