Depending on the quadrature signals, the direction is decoded and allows to count up or down in timer/counter
channels 0 and 1. The direction status is reported on TC_QISR.
36.6.14.5 Speed Measurement
When SPEEDEN is set in the TC_BMR, the speed measure is enabled on channel 0.
A time base must be defined on channel 2 by writing the TC_RC2 period register. Channel 2 must be configured in
Waveform mode (WAVE bit set) in TC_CMR2. The WAVSEL field must be defined with 0x10 to clear the counter
by comparison and matching with TC_RC value. Field ACPC must be defined at 0x11 to toggle TIOA output.
This time base is automatically fed back to TIOA of channel 0 when QDEN and SPEEDEN are set.
Channel 0 must be configured in Capture mode (WAVE = 0 in TC_CMR0). The ABETRG bit of TC_CMR0 must be
configured at 1 to select TIOA as a trigger for this channel.
EDGTRG must be set to 0x01, to clear the counter on a rising edge of the TIOA signal and field LDRA must be set
accordingly to 0x01, to load TC_RA0 at the same time as the counter is cleared (LDRB must be set to 0x01). As a
consequence, at the end of each time base period the differentiation required for the speed calculation is
performed.
The process must be started by configuring bits CLKEN and SWTRG in the TC_CCR.
The speed can be read on field RA in TC_RA0.
Channel 1 can still be used to count the number of revolutions of the motor.
36.6.15 2-bit Gray Up/Down Counter for Stepper Motor
Each channel can be independently configured to generate a 2-bit gray count waveform on corresponding TIOA,
TIOB outputs by means of the GCEN bit in TC_SMMRx.
Up or Down count can be defined by writing bit DOWN in TC_SMMRx.
It is mandatory to configure the channel in Waveform mode in the TC_CMR.
The period of the counters can be programmed in TC_RCx.
Figure 36-20. 2-bit Gray Up/Down Counter
TIOAx
TIOBx
DOWNx
TC_RCx
WAVEx = GCENx =1