36.6.11.1 WAVSEL = 00
When WAVSEL = 00, the value of TC_CV is incremented from 0 to 2
32
-1. Once 2
32
-1 has been reached, the value
of TC_CV is reset. Incrementation of TC_CV starts again and the cycle continues. See Figure 36-7.
An external event trigger or a software trigger can reset the value of TC_CV. It is important to note that the trigger
may occur at any time. See Figure 36-8.
RC Compare cannot be programmed to generate a trigger in this configuration. At the same time, RC Compare
can stop the counter clock (CPCSTOP = 1 in TC_CMR) and/or disable the counter clock (CPCDIS = 1 in
TC_CMR).
Figure 36-7. WAVSEL = 00 without trigger
Figure 36-8. WAVSEL = 00 with Trigger
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with 0xFFFF
0xFFFF
Waveform Examples
Time
Counter Value
R
C
R
B
R
A
TIOB
TIOA
Counter cleared by compare match with 0xFFFF
0xFFFF
Waveform Examples
Counter cleared by trigger