Datasheet
481
SAM3X / SAM3A [DATASHEET]
Atmel-11057C-ATARM-SAM3X-SAM3A-Datasheet_23-Mar-15
• RECERR4: Recoverable Error in the page between the 1024th and the 1279th bytes or between the 2048th and
the 2559th bytes
Fixed to 0 if
TYPECORREC = 0.
0: No Errors Detected.
1: Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise multiple uncorrected errors
were detected.
• ECCERR4: ECC Error in the page between the 1024th and the 1279th bytes or between the 2048th and the
2559th bytes
Fixed to 0 if
TYPECORREC = 0.
0: No Errors Detected.
1: A single bit error occurred in the ECC bytes.
Read ECC Parity 4 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR4: Multiple Error in the page between the 1024th and the 1279th bytes or between the 2048th and the
2559th bytes
Fixed to 0 if
TYPECORREC = 0.
0: No Multiple Errors Detected.
1: Multiple Errors Detected.
• RECERR5: Recoverable Error in the page between the 1280th and the 1535th bytes or between the 2560th and
the 3071st bytes
Fixed to 0 if
TYPECORREC = 0.
0: No Errors Detected.
1: Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise multiple uncorrected errors
were detected
• ECCERR5: ECC Error in the page between the 1280th and the 1535th bytes or between the 2560th and the
3071st bytes
Fixed to 0 if
TYPECORREC = 0.
0: No Errors Detected.
1: A single bit error occurred in the ECC bytes.
Read ECC Parity 5 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR5: Multiple Error in the page between the 1280th and the 1535th bytes or between the 2560th and the
3071st bytes
Fixed to 0 if
TYPECORREC = 0.
0: No Multiple Errors Detected.
1: Multiple Errors Detected.