Datasheet

377
SAM3X / SAM3A [DATASHEET]
Atmel-11057C-ATARM-SAM3X-SAM3A-Datasheet_23-Mar-15
DST_INCR: Incrementing, Decrementing or Fixed Address for the Destination
•IEN
If this bit is cleared, when the buffer transfer is completed, the BTCx flag is set in the EBCISR status register. This bit is
active low.
Value Name Description
00 INCREMENTING The destination address is incremented
01 DECREMENTING The destination address is decremented
10 FIXED The destination address remains unchanged