Fault Confinement
To distinguish between temporary and permanent failures, every CAN controller has two error counters: REC
(Receive Error Counter) and TEC (Transmit Error Counter). The two counters are incremented upon detected
errors and are decremented upon correct transmissions or receptions, respectively. Depending on the counter
values, the state of the node changes: the initial state of the CAN controller is Error Active, meaning that the
controller can send Error Active flags. The controller changes to the Error Passive state if there is an accumulation
of errors. If the CAN controller fails or if there is an extreme accumulation of errors, there is a state transition to Bus
Off.
Figure 40-7. Line Error Mode
An error active unit takes part in bus communication and sends an active error frame when the CAN controller
detects an error.
An error passive unit cannot send an active error frame. It takes part in bus communication, but when an error is
detected, a passive error frame is sent. Also, after a transmission, an error passive unit waits before initiating
further transmission.
A bus off unit is not allowed to have any influence on the bus.
For fault confinement, two errors counters (TEC and REC) are implemented. These counters are accessible via
the CAN_ECR register. The state of the CAN controller is automatically updated according to these counter
values. If the CAN controller is in Error Active state, then the ERRA bit is set in the CAN_SR register. The
corresponding interrupt is pending while the interrupt is not masked in the CAN_IMR register. If the CAN controller
is in Error Passive Mode, then the ERRP bit is set in the CAN_SR register and an interrupt remains pending while
the ERRP bit is set in the CAN_IMR register. If the CAN is in Bus Off Mode, then the BOFF bit is set in the
CAN_SR register. As for ERRP and ERRA, an interrupt is pending while the BOFF bit is set in the CAN_IMR
register.
When one of the error counters values exceeds 96, an increased error rate is indicated to the controller through
the WARN bit in CAN_SR register, but the node remains error active. The corresponding interrupt is pending while
the interrupt is set in the CAN_IMR register.
Refer to the Bosch CAN specification v2.0 for details on fault confinement.
Error Interrupt Handler
WARN, BOFF, ERRA and ERRP (CAN_SR) represent the current status of the CAN bus and are not latched.
They reflect the current TEC and REC (CAN_ECR) values as described in Section “Fault Confinement” on page
1196.
Based on that, if these bits are used as an interrupt, the user can enter into an interrupt and not see the
corresponding status register if the TEC and REC counter have changed their state. When entering Bus Off Mode,
the only way to exit from this state is 128 occurrences of 11 consecutive recessive bits or a CAN controller reset.
ERROR
ACTIVE
ERROR
PASSIVE
BUS OFF
TEC > 255
Init
TEC > 127
or
REC > 127
TEC < 127
and
REC < 127
128 occurences of 11 consecutive recessive bits
or
CAN controller reset