SJW is programmable to be the minimum of PHASE SEG1 and 4 TQ.
If the SMP field in the CAN_BR register is set, then the incoming bit stream is sampled three times with a period of
half a CAN clock period, centered on sample point.
In the CAN controller, the length of a bit on the CAN bus is determined by the parameters (BRP, PROPAG,
PHASE1 and PHASE2).
The time quantum is calculated as follows:
Note: The BRP field must be within the range [1, 0x7F], i.e., BRP = 0 is not authorized.
To compensate for phase shifts between clock oscillators of different controllers on the bus, the CAN controller
must resynchronize on any relevant signal edge of the current transmission. The resynchronization shortens or
lengthens the bit time so that the position of the sample point is shifted with regard to the detected edge. The
resynchronization jump width (SJW) defines the maximum of time by which a bit period may be shortened or
lengthened by resynchronization.
Figure 40-5. CAN Bit Timing
t
BIT
t
CSC
t
PRS
t
PHS1
t
PHS2
++ +=
t
CSC
BRP 1+()MCK=
t
PRS
t
CSC
PROPAG 1+()×=
t
PHS1
t
CSC
PHASE1 1+()×=
t
PHS2
t
CSC
PHASE2 1+()×=
t
SJW
t
CSC
SJW 1+()×=
SYNC_
SEG
PROP_SEG PHASE_SEG1 PHASE_SEG2
NOMINAL BIT TIME
Sample Point
Transmission Point
MCK
CAN Clock
t
CSC
t
PRS
t
PHS1
t