Datasheet
SAM3X / SAM3A [DATASHEET]
Atmel-11057C-ATARM-SAM3X-SAM3A-Datasheet_23-Mar-15
1160
39.6.3.13 Host Pipe x Configuration Register
Name: UOTGHS_HSTPIPCFGx [x=0..9]
Address: 0x400AC500
Access: Read-write
• INTFRQ: Pipe Interrupt Request Frequency
This field contains the maximum value in millisecond of the polling period for an Interrupt Pipe.
This value has no effect for a non-Interrupt Pipe.
This field is cleared upon sending a USB reset.
• BINTERVAL: bInterval parameter for the Bulk-Out/Ping transaction
This field contains the Ping/Bulk-out period.
• If BINTERVAL>0 and PINGEN=1, one PING token is sent every BINTERVAL micro-frame until it is ACKed by the
peripheral.
• If BINTERVAL=0 and PINGEN=1, multiple consecutive PING token is sent in the same micro-frame until it is ACKed.
• If BINTERVAL>0 and PINGEN=0, one OUT token is sent every BINTERVAL micro-frame until it is ACKed by the
peripheral.
• If BINTERVAL=0 and PINGEN=0, multiple consecutive OUT token is sent in the same micro-frame until it is ACKed.
This value must be in the range from 0 to 255.
• PINGEN: Ping Enable
This bit is relevant for High-speed Bulk-out transaction only (including the control data stage and the control status stage).
Writing a zero to this bit will disable the ping protocol.
Writing a one to this bit will enable the ping mechanism according to the USB 2.0 standard.
This bit is cleared upon sending a USB reset.
•
PEP
NUM: Pipe Endpoint Number
This field contains the number of the endpoint targeted by the pipe. This value is from 0 to 10.
This field is cleared upon sending a USB reset.
31 30 29 28 27 26 25 24
INTFRQ/BINTERVAL
23 22 21 20 19 18 17 16
– – – PINGEN PEPNUM
15 14 13 12 11 10 9 8
– – PTYPE – AUTOSW PTOKEN
76543210
– PSIZE PBK ALLOC –