Datasheet

1033
SAM3X / SAM3A [DATASHEET]
Atmel-11057C-ATARM-SAM3X-SAM3A-Datasheet_23-Mar-15
38.7.27 PWM Fault Protection Enable Register 1
Name: PWM_FPE1
Address: 0x4009406C
Access: Read-write
This register can only be written if the bits WPSWS5 and WPHWS5 are cleared in “PWM Write Protect Status Register” on
page 1039.
Only the first 6 bits (number of fault input pins) of fields FPE0, FPE1, FPE2 and FPE3 are significant.
FPEx: Fault Protection Enable for channel x (fault input bit varies from 0 to 5)
For each field bit y (fault input number):
0 = Fault y is not used for the Fault Protection of cha nnel x.
1 = Fault y is used for the Fault Protection of channel x.
CAUTION:
To prevent an unexpected activation of the Fault Protection, the bit y of FPEx field can be set to “1” only if the
corresponding FPOL bit has been previously configured to its final value in “PWM Fault Mode Register” on page 1029.
31 30 29 28 27 26 25 24
FPE3
23 22 21 20 19 18 17 16
FPE2
15 14 13 12 11 10 9 8
FPE1
76543210
FPE0