Datasheet

SAM3X / SAM3A [DATASHEET]
Atmel-11057C-ATARM-SAM3X-SAM3A-Datasheet_23-Mar-15
1016
38.7.10 PWM Sync Channels Update Control Register
Name: PWM_SCUC
Address: 0x40094028
Access: Read-write
UPDULOCK: Synchronous Channels Update Unlock
0 = No effect
1 = If the UPDM field is set to “0” in “PWM Sync Channels Mode Register” on page 1014, writing the UPDULOCK bit to “1”
triggers the update of the period value, the duty-cycle and the dead-time values of synchronous channels at the beginning
of the next PWM period. If the field UPDM is set to “1” or “2”, writing the UPDULOCK bit to “1” triggers only the update of
the period value and of the dead-time values of synchronous channels.
This bit is automatically reset when the update is done.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
–––––––UPDULOCK