Datasheet

Table Of Contents
299
ATmega640/V-1280/V-1281/V-2560/V-2561/V [DATASHEET]
2549Q–AVR–02/2014
When JTAG IR contains EXTEST or SAMPLE_PRELOAD the clock is not sent out on the port pins even if the
CKOUT fuse is programmed. Even though the clock is output when the JTAG IR contains SAMPLE_PRELOAD,
the clock is not sampled by the boundary scan.
Figure 28-3. Boundary-scan Cell for Bi-directional Port Pin with Pull-up Function.
DQ DQ
G
0
1
0
1
DQ DQ
G
0
1
0
1
0
1
Port Pin (PXn)
Vcc
EXTEST
To Next Cell
ShiftDR
Output Control (OC)
Output Data (OD)
Input Data (ID)
From Last Cell
UpdateDRClockDR
FF1 LD1
LD0FF0
0
1
Pull-up Enable (PUE)