Datasheet

20.11.4. CAN General Interrupt Enable Register
Name:  CANGIE
Offset:  0xDB
Reset:  0x0
Property:
 
R/W
Bit 7 6 5 4 3 2 1 0
ENIT ENBOFF ENRX ENTX ENERR ENBX ENERG ENOVRT
Access
Reset 0 0 0 0 0 0 0 0
Bit 7 – ENIT: Enable all Interrupts
Except for CAN Timer Overrun Interrupt
Value Description
0 Interrupt disabled
1 CANIT interrupt enabled
Bit 6 – ENBOFF: Enable Bus Off Interrupt
Value Description
0 Interrupt disabled
1 Bus off interrupt enabled
Bit 5 – ENRX: Enable Receive Interrupt
Value Description
0 Interrupt disabled
1 Receive interrupt enabled
Bit 4 – ENTX: Enable Transmit Interrupt
Value Description
0 Interrupt disabled
1 Transmit interrupt enabled
Bit 3 – ENERR: Enable MOb Errors Interrupt
Value Description
0 Interrupt disabled
1 MOb errors interrupt enabled
Bit 2 – ENBX: Enable Frame Buffer Interrupt
Value Description
0 Interrupt disabled
1 Frame buffer interrupt enabled
Bit 1 – ENERG: Enable General Errors Interrupt
Atmel ATmega16M1/32M1/64M1 [DATASHEET]
Atmel-8209F-ATmega16M1/32M1/64M1_Datasheet_Complete-10/2016