Datasheet

ATmega164A/PA/324A/PA/644A/PA/1284/P
2018 Microchip Technology Inc. Data Sheet Complete DS40002070A-page 114
Bit 2 – OCIE0B: Timer/Counter Output Compare Match B Interrupt Enable
When the OCIE0B bit is written to one, and the I-bit in the Status Register is set, the Timer/Counter Compare
Match B interrupt is enabled. The corresponding interrupt is executed if a Compare Match in Timer/Counter
occurs, that is, when the OCF0B bit is set in the Timer/Counter Interrupt Flag Register – TIFR0.
Bit 1 – OCIE0A: Timer/Counter0 Output Compare Match A Interrupt Enable
When the OCIE0A bit is written to one, and the I-bit in the Status Register is set, the Timer/Counter0 Compare
Match A interrupt is enabled. The corresponding interrupt is executed if a Compare Match in Timer/Counter0
occurs, that is, when the OCF0A bit is set in the Timer/Counter 0 Interrupt Flag Register – TIFR0.
Bit 0 – TOIE0: Timer/Counter0 Overflow Interrupt Enable
When the TOIE0 bit is written to one, and the I-bit in the Status Register is set, the Timer/Counter0 Overflow
interrupt is enabled. The corresponding interrupt is executed if an overflow in Timer/Counter0 occurs, that is,
when the TOV0 bit is set in the Timer/Counter 0 Interrupt Flag Register – TIFR0.
15.9.7 TIFR0 – Timer/Counter 0 Interrupt Flag Register
Bits 7:3 – Reserved
These bits are reserved and will always read as zero.
Bit 2 – OCF0B: Timer/Counter 0 Output Compare B Match Flag
The OCF0B bit is set when a Compare Match occurs between the Timer/Counter and the data in OCR0B –
Output Compare Register0 B. OCF0B is cleared by hardware when executing the corresponding interrupt
handling vector. Alternatively, OCF0B is cleared by writing a logic one to the flag. When the I-bit in SREG,
OCIE0B (Timer/Counter Compare B Match Interrupt Enable), and OCF0B are set, the Timer/Counter Compare
Match Interrupt is executed.
Bit 1 – OCF0A: Timer/Counter 0 Output Compare A Match Flag
The OCF0A bit is set when a Compare Match occurs between the Timer/Counter0 and the data in OCR0A –
Output Compare Register0. OCF0A is cleared by hardware when executing the corresponding interrupt
handling vector. Alternatively, OCF0A is cleared by writing a logic one to the flag. When the I-bit in SREG,
OCIE0A (Timer/Counter0 Compare Match Interrupt Enable), and OCF0A are set, the Timer/Counter0 Compare
Match Interrupt is executed.
Bit 0 – TOV0: Timer/Counter0 Overflow Flag
The bit TOV0 is set when an overflow occurs in Timer/Counter0. TOV0 is cleared by hardware when executing
the corresponding interrupt handling vector. Alternatively, TOV0 is cleared by writing a logic one to the flag.
When the SREG I-bit, TOIE0 (Timer/Counter0 Overflow Interrupt Enable), and TOV0 are set, the
Timer/Counter0 Overflow interrupt is executed.
The setting of this flag is dependent of the WGM02:0 bit setting. Refer to Table 15-8, ”Waveform Generation
mode bit description” on page 111.
Bit 76543210
0x15 (0x35)
–OCF0BOCF0ATOV0 TIFR0
Read/Write RRRRRR/WR/WR/W
Initial Value00000000