ATmega164A/PA/324A/PA/644A/PA/1284/P
2018 Microchip Technology Inc. Data Sheet Complete DS40002070A-page 100
decrement) its value. The Timer/Counter is inactive when no clock source is selected. The output from the Clock
Select logic is referred to as the timer clock (clk
T0
).
The double buffered Output Compare Registers (OCR0A and OCR0B) are compared with the Timer/Counter
value at all times. The result of the compare can be used by the Waveform Generator to generate a PWM or
variable frequency output on the Output Compare pins (OC0A and OC0B). See Section “15.5” on page 101 for
details. The Compare Match event will also set the Compare Flag (OCF0A or OCF0B) which can be used to
generate an Output Compare interrupt request.
15.2.2 Definitions
Many register and bit references in this section are written in general form. A lower case “n” replaces the
Timer/Counter number, in this case 0. A lower case “x” replaces the Output Compare Unit, in this case Compare
Unit A or Compare Unit B. However, when using the register or bit defines in a program, the precise form must
be used, that is, TCNT0 for accessing Timer/Counter0 counter value and so on.
The definitions in Table 15-1 are also used extensively throughout the document.
15.3 Timer/Counter Clock Sources
The Timer/Counter can be clocked by an internal or an external clock source. The clock source is selected by
the Clock Select logic which is controlled by the Clock Select (CS02:0) bits located in the Timer/Counter Control
Register (TCCR0B). For details on clock sources and prescaler, see ”Timer/Counter Prescaler” on page 158.
15.4 Counter Unit
The main part of the 8-bit Timer/Counter is the programmable bi-directional counter unit. Figure 15-2 shows a
block diagram of the counter and its surroundings.
Figure 15-2. Counter Unit block diagram
Signal description (internal signals):
count Increment or decrement TCNT0 by 1.
direction Select between increment and decrement.
clear Clear TCNT0 (set all bits to zero).
Table 15-1. Definitions
BOTTOM The counter reaches the BOTTOM when it becomes 0x00.
MAX The counter reaches its MAXimum when it becomes 0xFF (decimal 255).
TOP
The counter reaches the TOP when it becomes equal to the highest value in the
count sequence. The TOP value can be assigned to be the fixed value 0xFF
(MAX) or the value stored in the OCR0A Register. The assignment is
dependent on the mode of operation.
DATA BUS
TCNTn Control Logic
count
TOVn
(Int.Req.)
Clock Select
top
Tn
Edge
Detector
( From Prescaler )
clk
Tn
bottom
direction
clear