Datasheet

SAM9G45 [DATASHEET]
Atmel-6438O-ATARM-SAM9G45-Datasheet_08-Dec-15
956
EOCXp: End of Conversion X Position
0: The pressure measurement is disabled or the Xp conversion is not finished.
1: The pressure measurement is enabled and the Xp conversion is complete
EOCZ1: End of Conversion Z1 Measure
0: The pressure measurement is disabled or the Z1 conversion is not finished.
1: The pressure measurement is enabled and the Z1 conversion is complete
EOCZ2: End of Conversion Z2 Measure
0: The pressure measurement is disabled or the Z2 conversion is not finished.
1: The pressure measurement is enabled and the Z2 conversion is complete
OVREXP: Overrun Error on X Position
0: No overrun error on the XP measure channel.
1: There has been an overrun error on the XP measure channel.
OVREZ1: Overrun Error on Z1 Measure
0: No overrun error on the Z1 measure channel.
1: There has been an overrun error on the Z1 measure channel.
OVREZ2: Overrun Error on Z2 Measure
0: No overrun error on the Z2 measure channel.
1: There has been an overrun error on the Z2 measure channel.