Datasheet

955
SAM9G45 [DATASHEET]
Atmel-6438O-ATARM-SAM9G45-Datasheet_08-Dec-15
39.11.8 TSADCC Status Register
Name: TSADCC_SR
Address: 0xFFFB001C
Access: Read-only
EOCx: End of Conversion x
0: Corresponding analog channel is disabled, or the conversion is not finished.
1: Corresponding analog channel is enabled and conversion is complete.
OVREx: Overrun Error x
0: No overrun error on the corresponding channel since the last read of TSADCC_SR.
1: There has been an overrun error on the corresponding channel since the last read of TSADCC_SR.
DRDY: Data Ready
0: No data has been converted since the last read of TSADCC_LCDR.
1: At least one data has been converted and is available in TSADCC_LCDR.
GOVRE: General Overrun Error
0: No General Overrun Error occurred since the last read of TSADCC_SR.
1: At least one General Overrun Error has occurred since the last read of TSADCC_SR.
ENDRX: End of RX Buffer
0: The Receive Counter Register has not reached 0 since the last write in TSADCC_RCR or TSADCC_RNCR.
1: The Receive Counter Register has reached 0 since the last write in TSADCC_RCR or TSADCC_RNCR.
RXBUFF: RX Buffer Full
0: TSADCC_RCR or TSADCC_RNCR have a value other than 0.
1: Both TSADCC_RCR and TSADCC_RNCR have a value of 0.
PENCNT: Pen Contact
0: No contact has been detected since the last read of TSADCC_SR or PENDET is at 0.
1: At least one contact has been detected since the last read of TSADCC_SR.
NOCNT: No Contact
0: No contact loss has been detected since the last read of TSADCC_SR or PENDET is at 0.
1: At least one contact loss has been detected since the last read of TSADCC_SR.
31 30 29 28 27 26 25 24
OVREZ2 OVREZ1 OVREXP EOCZ2 EOCZ1 EOCXP
23 22 21 20 19 18 17 16
NOCNT PENCNT RXBUFF ENDRX GOVRE DRDY
15 14 13 12 11 10 9 8
OVRE7 OVRE6 OVRE5 OVRE4 OVRE3 OVRE2 OVRE1 OVRE0
76543210
EOC7 EOC6 EOC5 EOC4 EOC3 EOC2 EOC1 EOC0