Datasheet
287
SAM9G45 [DATASHEET]
Atmel-6438O-ATARM-SAM9G45-Datasheet_08-Dec-15
• ECCERR12: ECC Error in the page between the 3072nd and the 3327th bytes
Fixed to 0 if
TYPECORREC = 0
0: No Errors Detected
1: A single bit error occurred in the ECC bytes.
Read ECC Parity 12 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR12: Multiple Error in the page between the 3072nd and the 3327th bytes
Fixed to 0 if TYPECORREC = 0.
0: No Multiple Errors Detected.
1: Multiple Errors Detected.
• RECERR13: Recoverable Error in the page between the 3328th and the 3583rd bytes
Fixed to 0 if TYPECORREC = 0.
0: No Errors Detected.
1: Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise multiple uncorrected errors
were detected.
• ECCERR13: ECC Error in the page between the 3328th and the 3583rd bytes
Fixed to 0 if TYPECORREC = 0.
0: No Errors Detected.
1: A single bit error occurred in the ECC bytes.
Read ECC Parity 13 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR13: Multiple Error in the page between the 3328th and the 3583rd bytes
Fixed to 0 if TYPECORREC = 0.
0: No Multiple Errors Detected.
1: Multiple Errors Detected.
• RECERR14: Recoverable Error in the page between the 3584th and the 3839th bytes
Fixed to 0 if TYPECORREC = 0.
0: No Errors Detected.
1: Errors Detected. If MUL_ERROR is 0, a single correctable error was detected. Otherwise, multiple uncorrected errors
were detected.
• ECCERR14: ECC Error in the page between the 3584th and the 3839th bytes
Fixed to 0 if TYPECORREC = 0.
0: No Errors Detected.
1: A single bit error occurred in the ECC bytes.
Read ECC Parity 14 register, the error occurred at the location which contains a 1 in the least significant 24 bits.
• MULERR14: Multiple Error in the page between the 3584th and the 3839th bytes
Fixed to 0 if TYPECORREC = 0.
0: No Multiple Errors Detected.
1: Multiple Errors Detected.