Datasheet

SAM9G20
DS60001516A-page 766 2017 Microchip Technology Inc.
Figure 40-22: MCI Timings
Table 40-46: MCI Timings
Symbol Parameter C
LOAD
Min Max Unit
MCI
1
CLK frequency at Data transfer Mode
25 pF 25
MHz100 pF 20
250 pF 20
CLK frequency at Identification Mode 400 kHz
CLK Low time 100 pF 10 ns
CLK High time 100 pF 10 ns
CLK Rise time 100 pF 10 ns
CLK Fall time 100 pF 10 ns
CLK Low time 250 pF 50 ns
CLK High time 250 pF 50 ns
CLK Rise time 250 pF 50 ns
CLK Fall time 250 pF 50 ns
MCI
2
Input hold time 3 ns
MCI
3
Input setup time 3 ns
MCI
4
Output change after CLK rising 5 ns
MCI
5
Output valid before CLK rising 5 ns
CLK
CMD_DAT Input
MCI
1
CMD_DAT Output
MCI
2
MCI
3
MCI
4
MCI
5
Shaded areas are not valid