38.4.3 ISI Status Register
Name: ISI_SR
Access: Read-only
SOF: Start of Frame
0: No start of frame has been detected.
1: A start of frame has been detected.
DIS: Image Sensor Interface Disable
0: The image sensor interface is enabled.
1: The image sensor interface is disabled and stops capturing data. The DMA controller and the core can still read the FIFOs.
SOFTRST: Software Reset
0: Software reset not asserted or not completed.
1: Software reset has completed successfully.
CDC_PND: Codec Request Pending
0: No request asserted.
1: A codec request is pending. If a codec request is asserted during a frame, the CDC_PND bit rises until the start of a new frame. The
capture is completed when the flag FO_C_EMP = 1.
CRC_ERR: CRC Synchronization Error
0: No CRC error in the embedded synchronization frame (SAV/EAV)
1: The CRC_SYNC is enabled in the control register and an error has been detected and not corrected. The frame is discarded and the
ISI waits for a new one.
FO_C_OVF: FIFO Codec Overflow
0: No overflow
1: An overrun condition has occurred in input FIFO on the codec path. The overrun happens when the FIFO is full and an attempt is made
to write a new sample to the FIFO.
FO_P_OVF: FIFO Preview Overflow
0: No overflow
1: An overrun condition has occurred in input FIFO on the preview path. The overrun happens when the FIFO is full and an attempt is
made to write a new sample to the FIFO.
FO_P_EMP
0:The DMA has not finished transferring all the contents of the preview FIFO.
1:The DMA has finished transferring all the contents of the preview FIFO.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––FR_OVRFO_C_EMP
76543210
FO_P_EMP FO_P_OVF FO_C_OVF CRC_ERR CDC_PND SOFTRST DIS SOF