30.7.1 TWI Control Register
Name: TWI_CR
Access: Write-only
START: Send a START Condition
0: No effect.
1: A frame beginning with a START bit is transmitted according to the features defined in the mode register.
This action is necessary when the TWI peripheral wants to read data from a slave. When configured in Master Mode with a write operation,
a frame is sent as soon as the user writes a character in the Transmit Holding Register (TWI_THR).
STOP: Send a STOP Condition
0: No effect.
1: STOP Condition is sent just after completing the current byte transmission in master read mode.
In single data byte master read, the START and STOP must both be set.
In multiple data bytes master read, the STOP must be set after the last data received but one.
In master read mode, if a NACK bit is received, the STOP is automatically performed.
In multiple data write operation, when both THR and shift register are empty, a STOP condition is automatically
sent.
MSEN: TWI Master Mode Enabled
0: No effect.
1: If MSDIS = 0, the master mode is enabled.
Note: Switching from Slave to Master mode is only permitted when TXCOMP = 1.
MSDIS: TWI Master Mode Disabled
0: No effect.
1: The master mode is disabled, all pending data is transmitted. The shifter and holding characters (if it contains data) are transmitted in
case of write operation. In read operation, the character being transferred must be completely received before disabling.
SVEN: TWI Slave Mode Enabled
0: No effect.
1: If SVDIS = 0, the slave mode is enabled.
Note: Switching from Master to Slave mode is only permitted when TXCOMP = 1.
SVDIS: TWI Slave Mode Disabled
0: No effect.
1: The slave mode is disabled. The shifter and holding characters (if it contains data) are transmitted in case of read operation. In write
operation, the character being transferred must be completely received before disabling.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
––––––––
15 14 13 12 11 10 9 8
––––––––
76543210
SWRST SVDIS SVEN MSDIS MSEN STOP START