Datasheet

SAM9G20
DS60001516A-page 294 2017 Microchip Technology Inc.
25.9.17 PLL Charge Pump Current Register
Name:PMC_PLLICPR
Access:Read/Write
ICPLLA: Charge Pump Current
To optimize clock performance, this field must be programmed as specified in Section 40.5.7 “PLL Characteristics”.
ICPLLB: Charge Pump Current
Must be set to 0.
31 30 29 28 27 26 25 24
––––––––
23 22 21 20 19 18 17 16
–––––––ICPLLB
15 14 13 12 11 10 9 8
––––––––
76543210
–––––––ICPLLA