DS60001516A-page 162 2017 Microchip Technology Inc.
Table 20-4 shows how the timing parameters are coded and their permitted range.
20.8.6 Reset Values of Timing Parameters
Table 20-8 “Register Mapping” gives the default value of timing parameters at reset.
20.8.7 Usage Restriction
The SMC does not check the validity of the user-programmed parameters. If the sum of SETUP and PULSE parameters is larger than the
corresponding CYCLE parameter, this leads to unpredictable behavior of the SMC.
For read operations:
Null but positive setup and hold of address and NRD and/or NCS can not be guaranteed at the memory interface because of the propa-
gation delay of theses signals through external logic and pads. If positive setup and hold values must be verified, then it is strictly recom-
mended to program non-null values so as to cover possible skews between address, NCS and NRD signals.
For write operations:
If a null hold value is programmed on NWE, the SMC can guarantee a positive hold of address, byte select lines, and NCS signal after the
rising edge of NWE. This is true for WRITE_MODE = 1 only. See Section 20.9.2 “Early Read Wait State”.
For read and write operations: a null value for pulse parameters is forbidden and may lead to unpredictable behavior.
In read and write cycles, the setup and hold time parameters are defined in reference to the address bus. For external devices that require
setup and hold time between NCS and NRD signals (read), or between NCS and NWE signals (write), these setup and hold times must
be converted into setup and hold times in reference to the address bus.
20.9 Automatic Wait States
Under certain circumstances, the SMC automatically inserts idle cycles between accesses to avoid bus contention or operation conflict.
20.9.1 Chip Select Wait States
The SMC always inserts an idle cycle between 2 transfers on separate chip selects. This idle cycle ensures that there is no bus contention
between the de-activation of one device and the activation of the next one.
During chip select wait state, all control lines are turned inactive: NBS0 to NBS3, NWR0 to NWR3, NCS[0..7], NRD lines are all set to 1.
Figure 20-16 illustrates a chip select wait state between access on Chip Select 0 and Chip Select 2.
Table 20-4: Coding and Range of Timing Parameters
Coded Value Number of Bits Effective Value
Permitted Range
Coded Value Effective Value
setup [5:0] 6 128 x setup[5] + setup[4:0] 0 ≤ 31 128 ≤ 128 + 31
pulse [6:0] 7 256 x pulse[6] + pulse[5:0] 0 ≤ 63 256 ≤ 256 + 63
cycle [8:0] 9 256 x cycle[8:7] + cycle[6:0] 0 ≤ 127
256 ≤ 256 + 127
512 ≤ 512 + 127
768 ≤ 768 + 127