Atmel-6062O-ATARM-SAM9261-Datasheet_21-Jun-16
37.9 Register Configuration Guide
Program the PIO Controller to enable LCD signals.
Enable the LCD controller clock in the Power Management Controller.
PMC_SCER = 1 << 17;//LCDC HCLK = HCK1
37.9.1 STN Mode Example
STN color(R,G,B) 320*240, 8-bit single scan, 70 frames/sec, Master clock = 60 MHz
Data rate: 320*240*70*3/8 = 2.016 MHz
HOZVAL= ((3*320)/8) - 1
LINEVAL= 240 -1
CLKVAL = (60 MHz/ (2*2.016 MHz)) - 1= 14
LCDCON1= CLKVAL << 12
LCDCON2 = LITTLEENDIAN | SINGLESCAN | STNCOLOR | DISP8BIT| PS8BPP;
LCDTIM1 = 0;
LCDTIM2 = 10 | (10 << 21);
LCDFRMCFG = (HOZVAL << 21) | LINEVAL;
DMAFRMCFG = (7 << 24) + (320 * 240 * 8) / 32;
37.9.2 TFT Mode Example
This example is based on the NEC TFT color LCD module NL6448BC20-08
.
TFT 640*480, 16-bit single scan, 60 frames/sec, pixel clock frequency = [21MHz..29MHz] with a typical value =
25.175 MHz.
The Master clock must be (2*(n + 1))*pixel clock frequency
HOZVAL = 640 - 1
LINEVAL = 480 - 1
If Master clock is 50 MHz
CLKVAL = (50 MHz/ (2*25.175 MHz)) - 1= 0
VFP = (12 -1), VBP = (31-1), VPW = (2-1), VHDLY= (2-1)
HFP = (16-2), HBP = (48 -1), HPW = (64-1)
LCDCON1= CLKVAL << 12
LCDCON2 = LITTLEENDIAN | CLKMOD | INVERT_CLK | INVERT_LINE | INVERT_FRM | PS16BPP |
SINGLESCAN | TFT
LCDTIM1 = VFP | (VBP << 8) | (VPW << 16) | (VHDLY << 24)
LCDTIM2 = HBP | (HPW << 8) | (HFP << 21)
LCDFRMCFG = (HOZVAL << 21) | LINEVAL
DMAFRMCFG = (7 << 24) + (640 * 480* 16) / 32;