Datasheet
413
SAM9261 [DATASHEET]
Atmel-6062O-ATARM-SAM9261-Datasheet_21-Jun-16
Clock Synchronization in Write Mode
The clock is tied low if the shift register and the TWI_RHR is full. If a STOP or REPEATED_START condition was
not detected, it is tied low until TWI_RHR is read.
Figure 30-29 describes the clock synchronization in Read mode.
Figure 30-29. Clock Synchronization in Write Mode
Notes: 1. At the end of the read sequence, TXCOMP is set after a STOP or after a REPEATED_START + an address different from
SADR.
2. SCLWS is automatically set when the clock synchronization mechanism is started and automatically reset when the
mechanism is finished.
Rd DATA0
Rd DATA1
Rd DATA2
SVACC
SVREAD
RXRDY
SCLWS
TXCOMP
DATA1
DATA2
SCL is stretched on the last bit of DATA1
As soon as a START is detected
TWCK
TWD
TWI_RHR
CLOCK is tied low by the TWI as long as RHR is full
DATA0 is not read in the RHR
ADRS SADR W ADATA 0A A DATA 2DATA1 S
NA