Datasheet
397
SAM9261 [DATASHEET]
Atmel-6062O-ATARM-SAM9261-Datasheet_21-Jun-16
30.8.5 Master Receiver Mode
The read sequence begins by setting the START bit. After the start condition has been sent, the master sends a 7-
bit slave address to notify the slave device. The bit following the slave address indicates the transfer direction, 1 in
this case (MREAD = 1 in TWI_MMR). During the acknowledge clock pulse (9th pulse), the master releases the
data line (HIGH), enabling the slave to pull it down in order to generate the acknowledge. The master polls the
data line during this clock pulse and sets the NACK bit in the status register if the slave does not acknowledge the
byte.
If an acknowledge is received, the master is then ready to receive data from the slave. After data has been
received, the master sends an acknowledge condition to notify the slave that the data has been received except
for the last data, after the stop condition. See Figure 30-9. When the RXRDY bit is set in the status register, a
character has been received in the receive-holding register (TWI_RHR). The RXRDY bit is reset when reading the
TWI_RHR.
When a single data byte read is performed, with or without internal address (IADR), the START and STOP bits
must be set at the same time. See Figure 30-9. When a multiple data byte read is performed, with or without
internal address (IADR), the STOP bit must be set after the next-to-last data received. See Figure 30-10. For
Internal Address usage see Section 30.8.6.
Figure 30-9. Master Read with One Data Byte
Figure 30-10. Master Read with Multiple Data Bytes
AS DADR R DATA N P
TXCOMP
Write START &
STOP Bit
RXRDY
Read RHR
TWD
N
AS DADR R DATA n A ADATA (n+1) A DATA (n+m)DATA (n+m)-1 PTWD
TXCOMP
Write START Bit
RXRDY
Write STOP Bit
after next-to-last data read
Read RHR
DATA n
Read RHR
DATA (n+1)
Read RHR
DATA (n+m)-1
Read RHR
DATA (n+m)