Datasheet

SAM9261 [DATASHEET]
Atmel-6062O-ATARM-SAM9261-Datasheet_21-Jun-16
306
27.5.3 Transmitter
27.5.3.1 Transmitter Reset, Enable and Disable
After device reset, the Debug Unit transmitter is disabled and it must be enabled before being used. The
transmitter is enabled by writing the control register DBGU_CR with the bit TXEN at 1. From this command, the
transmitter waits for a character to be written in the Transmit Holding Register DBGU_THR before actually starting
the transmission.
The programmer can disable the transmitter by writing DBGU_CR with the bit TXDIS at 1. If the transmitter is not
operating, it is immediately stopped. However, if a character is being processed into the Shift Register and/or a
character has been written in the Transmit Holding Register, the characters are completed before the transmitter is
actually stopped.
The programmer can also put the transmitter in its reset state by writing the DBGU_CR with the bit RSTTX at 1.
This immediately stops the transmitter, whether or not it is processing characters.
27.5.3.2 Transmit Format
The Debug Unit transmitter drives the pin DTXD at the baud rate clock speed. The line is driven depending on the
format defined in the Mode Register and the data stored in the Shift Register. One start bit at level 0, then the 8
data bits, from the lowest to the highest bit, one optional parity bit and one stop bit at 1 are consecutively shifted
out as shown on the following figure. The field PARE in the mode register DBGU_MR defines whether or not a
parity bit is shifted out. When a parity bit is enabled, it can be selected between an odd parity, an even parity, or a
fixed space or mark bit.
Figure 27-10. Character Transmission
27.5.3.3 Transmitter Control
When the transmitter is enabled, the bit TXRDY (Transmitter Ready) is set in the status register DBGU_SR. The
transmission starts when the programmer writes in the Transmit Holding Register DBGU_THR, and after the
written character is transferred from DBGU_THR to the Shift Register. The bit TXRDY remains high until a second
character is written in DBGU_THR. As soon as the first character is completed, the last character written in
DBGU_THR is transferred into the shift register and TXRDY rises again, showing that the holding register is
empty.
When both the Shift Register and the DBGU_THR are empty, i.e., all the characters written in DBGU_THR have
been processed, the bit TXEMPTY rises after the last stop bit has been completed.
D0 D1 D2 D3 D4 D5 D6 D7
DTXD
Start
Bit
Parity
Bit
Stop
Bit
Example: Parity enabled
Baud Rate
Clock