24.8 Clock Switching Details
24.8.1 Master Clock Switching Timings
Table 24-1 and Table 24-2 give the worst case timings required for the Master Clock to switch from one selected
clock to another one. This is in the event that the prescaler is de-activated. When the prescaler is activated, an
additional time of 64 clock cycles of the new selected clock has to be added.
Notes: 1. PLL designates either the PLL A or the PLL B Clock.
2. PLLCOUNT designates either PLLACOUNT or PLLBCOUNT.
Table 24-1. Clock Switching Timings (Worst Case)
From Main Clock SLCK PLL Clock
To
Main Clock
4 x SLCK +
2.5 x Main Clock
3 x PLL Clock +
4 x SLCK +
1 x Main Clock
SLCK
0.5 x Main Clock +
4.5 x SLCK
3 x PLL Clock +
5 x SLCK
PLL Clock
0.5 x Main Clock +
4 x SLCK +
PLLCOUNT x SLCK +
2.5 x PLLx Clock
2.5 x PLL Clock +
5 x SLCK +
PLLCOUNT x SLCK
2.5 x PLL Clock +
4 x SLCK +
PLLCOUNT x SLCK
Table 24-2. Clock Switching Timings Between Two PLLs (Worst Case)
From PLLA Clock PLLB Clock
To
PLLA Clock
2.5 x PLLA Clock +
4 x SLCK +
PLLACOUNT x SLCK
3 x PLLA Clock +
4 x SLCK +
1.5 x PLLA Clock
PLLB Clock
3 x PLLB Clock +
4 x SLCK +
1.5 x PLLB Clock
2.5 x PLLB Clock +
4 x SLCK +
PLLBCOUNT x SLCK