- 14.2 Overview
- 14.3 Timer/Counter Clock Sources
- 14.4 Counter Unit
- 14.5 Output Compare Unit
- 14.6 Compare Match Output Unit
- 14.7 Modes of Operation
- 14.8 Timer/Counter Timing Diagrams
- 14.9 8-bit Timer/Counter Register Description
- 14.10 Asynchronous operation of the Timer/Counter2
- 14.11 Timer/Counter2 Prescaler
- 15. Output Compare Modulator - OCM
- 16. Serial Peripheral Interface - SPI
- 17. USART (USART0 and USART1)
- 17.1 Features
- 17.2 Overview
- 17.3 Dual USART
- 17.4 Clock Generation
- 17.5 Serial Frame
- 17.6 USART Initialization
- 17.7 Data Transmission - USART Transmitter
- 17.8 Data Reception - USART Receiver
- 17.9 Asynchronous Data Reception
- 17.10 Multi-processor Communication Mode
- 17.11 USART Register Description
- 17.12 Examples of Baud Rate Setting
- 18. Two-wire Serial Interface
- 19. Controller Area Network - CAN
- 20. Analog Comparator
- 21. Analog to Digital Converter - ADC
- 22. JTAG Interface and On-chip Debug System
- 23. Boundary-scan IEEE 1149.1 (JTAG)
- 24. Boot Loader Support - Read-While-Write Self-Programming
- 25. Memory Programming
- 26. Electrical Characteristics (1)
- 26.1 Absolute Maximum Ratings*
- 26.2 DC Characteristics
- 26.3 External Clock Drive Characteristics
- 26.4 Maximum Speed vs. VCC
- 26.5 Two-wire Serial Interface Characteristics
- 26.6 SPI Timing Characteristics
- 26.7 CAN Physical Layer Characteristics
- 26.8 ADC Characteristics
- 26.9 External Data Memory Characteristics
- 26.10 Parallel Programming Characteristics
- 27. Decoupling Capacitors
- 28. AT90CAN32/64/128 Typical Characteristics
- 28.1 Active Supply Current
- 28.2 Idle Supply Current
- 28.3 Power-down Supply Current
- 28.4 Power-save Supply Current
- 28.5 Standby Supply Current
- 28.6 Pin Pull-up
- 28.7 Pin Driver Strength
- 28.8 Pin Thresholds and Hysteresis
- 28.9 BOD Thresholds and Analog Comparator Offset
- 28.10 Internal Oscillator Speed
- 28.11 Current Consumption of Peripheral Units
- 28.12 Current Consumption in Reset and Reset Pulse Width
- 29. Register Summary
- 30. Instruction Set Summary
- 31. Ordering Information
- 32. Packaging Information
- 33. Errata
- 34. Datasheet Revision History for AT90CAN32/64/128
- 34.1 Changes from 7679G - 03/08 to 7679H - 08/08
- 34.2 Changes from 7679F - 11/07 to 7679G - 03/08
- 34.3 Changes from 7679E - 07/07 to 7679F - 11/07
- 34.4 Changes from 7679D - 02/07 to 7679E - 07/07
- 34.5 Changes from 7679C - 01/07 to 7679D - 02/07
- 34.6 Changes from 7679B - 11/06 to 7679C - 01/07
- 34.7 Changes from 7679A - 10/06 to 7679B - 11/06
- 34.8 Document Creation

248
7679H–CAN–08/08
AT90CAN32/64/128
19.7 Error Management
19.7.1 Fault Confinement
The CAN channel may be in one of the three following states:
• Error active (default):
The CAN channel takes part in bus communication and can send an active error frame when
the CAN macro detects an error.
• Error passive:
The CAN channel cannot send an active error frame. It takes part in bus communication, but
when an error is detected, a passive error frame is sent. Also, after a transmission, an error
passive unit will wait before initiating further transmission.
• Bus off:
The CAN channel is not allowed to have any influence on the bus.
For fault confinement, a transmit error counter (TEC) and a receive error counter (REC) are
implemented. BOFF and ERRP bits give the information of the state of the CAN channel. Setting
BOFF to one may generate an interrupt.
Figure 19-12. Line Error Mode
Note: More than one REC/TEC change may apply during a given message transfer.
19.7.2 Error Types
• BERR: Bit error. The bit value which is monitored is different from the bit value sent.
Note: Exceptions:
- Recessive bit sent monitored as dominant bit during the arbitration field and the acknowl-
edge slot.
- Detecting a dominant bit during the sending of an error frame.
• SERR: Stuff error. Detection of more than five consecutive bit with the same polarity.
• CERR: CRC error (Rx only). The receiver performs a CRC check on every destuffed received
message from the start of frame up to the data field. If this checking does not match with the
destuffed CRC field, an CRC error is set.
• FERR: Form error. The form error results from one (or more) violations of the fixed form of
the following bit fields:
– CRC delimiter
– acknowledgement delimiter
ERRP = 1
BOFF = 0
Error
Active
Error
Passive
Bus
Off
TEC > 127 or
REC > 127
128 occurrences
of 11 consecutive
recessive bit
Reset
interrupt - BOFFIT
TEC > 255
TEC < 127 and
REC < 127
ERRP = 0
BOFF = 0
ERRP = 0
BOFF = 1