Datasheet

96
32117D–AVR-01/12
AT32UC3C
8.6.4 Interrupt Status Register
Name: ISR
Access Type: Read-only
Offset: 0x000C
Reset Value: 0x00000000
0: The corresponding interrupt is cleared.
1: The corresponding interrupt is pending.
This bit is cleared when the corresponding bit in ICR is written to one.
This bit is set when the corresponding interrupt occurs.
31 30 29 28 27 26 25 24
AE-------
23 22 21 20 19 18 17 16
--------
15 14 13 12 11 10 9 8
-----
PLL1_LOCK
LOST
PLL0_LOCK
LOST
BOD50DET
76543210
BOD33DET BODDET PLL1_LOCK PLL0_LOCK
RCOSC8MR
DY
OSC32RDY OSC1RDY OSC0RDY