Datasheet
798
32117D–AVR-01/12
AT32UC3C
29.7.23 MOb TX Interrupt Status Register
Name:MTXISR
Access type: Read-only
Offset: 0x58
Reset Value: 0x00000000
• TXOK: Transmission Successful
0: The corresponding MOb has not completed a transmission.
1: The corresponding MOb has completed a transmission (same bit as MOBSRn.TXOK).
This bit is cleared when the corresponding bit in MTXISCR is written to one.
This bit is set when the corresponding MOb has completed a transmission.
31 30 29 28 27 26 25 24
TXOK[31:24]
23 22 21 20 19 18 17 16
TXOK[23:16]
15 14 13 12 11 10 9 8
TXOK[15:8]
76543210
TXOK[7:0]