Datasheet

776
32117D–AVR-01/12
AT32UC3C
29.7.1 Version Register
Name: VERSION
Access type: Read-only
Offset: 0x00
Reset Value: -
MNCH0: MOb Number Channel #0
Number of MOb for channel 0 (1..32).
CHNO: Channel Number
Number of CAN channels (1..5).
Variant: Variant Number
Reserved. No functionality associated.
VERSION: Version Number
Version number of the module. No functionality associated.
31 30 29 28 27 26 25 24
- - MNCH0
23 22 21 20 19 18 17 16
- CHNO VARIANT
15 14 13 12 11 10 9 8
- - - - VERSION[11:8]
76543210
VERSION[7:0]