24.7.16 Single Collision Frames Register
Name: SCF
Access Type: Read/Write
Offset: 0x44
Reset Value: 0x00000000
•
SCF: Single Collision Frames
Number of frames experiencing a single collision before being successfully transmitted, i.e., no underrun.
31 30 29 28 27 26 25 24
--------
23 22 21 20 19 18 17 16
--------
15 14 13 12 11 10 9 8
SCF[15:8]
76543210
SCF[7:0]