Datasheet
1173
32117D–AVR-01/12
AT32UC3C
37.7.16 Timer Register Channel B
Name:
TRB
Access Type: Read/Write
Offset: 0x3C
Reset Value: 0x00000000
• TRL: DAC Timer Reload
Write this bit to one to re-initialize the counter.
• TCD: DAC Timer Count Down Value
These bits are used to program the timing counter countdown value.
The timer counts from this value down to zero and then issues a trigger signal before reloading the count register.
31 30 29 28 27 26 25 24
TRL-------
23 22 21 20 19 18 17 16
--------
15 14 13 12 11 10 9 8
--------
76543210
TCD