Datasheet
110
32117D–AVR-01/12
AT32UC3C
8.6.13 5V BOD Control Register
Name: BOD50
Access Type: Read/Write
Offset: 0x0038
Reset Value: 0x00000000
• SFV: Store Final Value
0: The register is read/write.
1: The register is read-only, to protect against further accidental writes.
• CTRL: BOD50 Control
0: BOD50 is off.
1: BOD50 is enabled.
• HYST: BOD50 Hysteresis
0: No hysteresis.
1: Hysteresis on.
• LEVEL: BOD50 Level
This field sets the triggering threshold of the BOD50. See Electrical Characteristics for actual voltage levels.
Note that any change to the LEVEL field of the BOD50 register should be done with the BOD50 deactivated to avoid spurious
reset or interrupt.
Note that this register is protected by a lock. To write to this register the UNLOCK register has to be written first. Please
refer to the UNLOCK register description for details.
31 30 29 28 27 26 25 24
SFV-------
23 22 21 20 19 18 17 16
--------
15 14 13 12 11 10 9 8
-------CTRL
76543210
- HYST LEVEL