Appendix A. Error Messages
In this section, the various “pop-up” errors that are found in the GUI will be discussed
in detail as to why they may occur, and the possible solutions for correcting the errors.
TABLE A-1: ERROR MESSAGES
Error
Number
Error Possible Solution
1.00.x Trouble reading the USB firmware
version
Unplug/plug the tool into the PC. Also make sure that
the PIC18F2550 is programmed with the proper HEX
file.
2.00.x Trouble reading the CAN firmware
version
Unplug/plug the tool into the PC. Also make sure that
the PIC18F2680 is programmed with the proper HEX
file.
3.00.x ID field is empty The value in the ID field can not be empty for a mes-
sage that a user is requesting to be transmitted. Enter a
valid value.
3.10.x DLC field is empty The value in the DLC field can not be empty for a mes-
sage that a user is requesting to be transmitted. Enter a
valid value.
3.20.x DATA field is empty The value in the Data field can not be empty for a mes-
sage that a user is requesting to be transmitted. Enter a
valid value. Remember, the DLC value drives how
many data bytes will be sent.
3.30.x PERIOD field is empty The value in the Period field can not be empty for a
message that a user is requesting to be transmitted.
Enter a valid value.
3.40.x REPEAT field is empty The value in the Repeat field can not be empty for a
message that a user is requesting to be transmitted.
Enter a valid value.
4.00.x Enter the Extended ID within the
following range (0x-1FFFFFFFx)
Enter a valid ID into the text field. The tool is expecting
a hexidecimal value for an extended ID in the range of
“0x-1FFFFFFFx”. When entering an extended ID, make
sure to append ‘x’ onto the ID.
4.02.x Enter the Extended ID within the
following range (0x-536870911x)
Enter a valid ID into the text field. The tool is expecting
a decimal value for an extended ID in the range of
“0x-536870911x”. When entering an extended ID,
make sure to append ‘x’ onto the ID.
4.04.x Enter the Standard ID within the
following range (0-7FF)
Enter a valid ID into the text field. The tool is expecting
a hexidecimal value for a standard ID in the range of
“0-7FF”. When entering an extended ID, make sure to
append ‘x’ onto the ID.
4.06.x Enter the Standard ID within the
following range (0-2047)
Enter a valid ID into the text field. The tool is expecting
a decimal value for a standard ID in the range of
“0-2048”. When entering an extended ID, make sure to
append ‘x’ onto the ID.