Datasheet
CAN Bus Analyzer User’s Guide
DS51848B-page 22 2011 Microchip Technology Inc.
3.4 FUTURE FEATURE – GROUP TRANSMIT FEATURE
To activate the Group Transmit window, select “GROUP TRANSMIT” from the main
Tools menu.
FIGURE 3-5: GROUP TRANSMIT WINDOW
The Group Transmit window allows the user to interact with other nodes on the CAN
BUS by transmitting messages. The user is able to transmit a limited group of mes-
sages in sequential order spaced out by user-defined timing in the Period field. All
messages can be unique to each other in terms of ID, DLC, Data bytes and time
between messages.
3.4.1 Steps to Transmit a Group of CAN Messages
1. Fill in the CAN message fields which include the ID, DLC and DATA for all
messages that will be transmitted
2. Ensure that the Periodic field is populated for each message (50 ms to 5000 ms).
This field represents the time between messages
3. Click on the Send button for that row. The row will be highlighted for the current
transmitted message