Datasheet
2009-2019 Microchip Technology Inc. DS20001711L-page 4
24AA01/24LC01B/24FC01
TABLE 1-2 AC CHARACTERISTICS
AC CHARACTERISTICS
Industrial (I): TA = -40°C to +85°C, VCC = +1.7V to +5.5V
Extended (E): TA = -40°C to +125°C, VCC = +2.5V to +5.5V (24LC01B)
Extended (E): TA = -40°C to +125°C, VCC = +1.7V to +5.5V (24FC01)
Param.
No.
Symbol Characteristic Min. Typ. Max. Units Conditions
1F
CLK Clock Frequency — — 400 kHz 2.5V ≤ VCC ≤ 5.5V
— — 100 kHz 1.7V ≤ V
CC < 2.5V (24AA01)
— — 1000 kHz 1.7V ≤ V
CC ≤ 5.5V (24FC01)
2THIGH Clock High Time 600 — — ns 2.5V ≤ VCC ≤ 5.5V
4000 — — ns 1.7V ≤ V
CC < 2.5V (24AA01)
260 — — ns 1.7V ≤ V
CC ≤ 5.5V (24FC01)
3TLOW Clock Low Time 1300 — — ns 2.5V ≤ VCC ≤ 5.5V
4700 — — ns 1.7V ≤ V
CC < 2.5V (24AA01)
500 — — ns 1.7V ≤ V
CC ≤ 5.5V (24FC01)
4TR SDA and SCL Rise Time — — 300 ns 2.5V ≤ VCC ≤ 5.5V (Note 1)
— — 1000 ns 1.7V ≤ V
CC < 2.5V (24AA01)
(Note 1)
— — 1000 ns 1.7V ≤ VCC ≤ 5.5V (24FC01)
(Note 1)
5T
F SDA and SCL Fall Time — — 300 ns (Note 1)
6THD:STA Start Condition Hold Time 600 — — ns 2.5V ≤ VCC ≤ 5.5V
4000 — — ns 1.7V ≤ V
CC < 2.5V (24AA01)
250 — — ns 1.7V ≤ V
CC ≤ 5.5V (24FC01)
7TSU:STA Start Condition Setup
Time
600 — — ns 2.5V ≤ VCC ≤ 5.5V
4700 — — ns 1.7V ≤ V
CC < 2.5V (24AA01)
250 — — ns 1.7V ≤ V
CC ≤ 5.5V (24FC01)
8THD:DAT Data Input Hold Time 0 — — ns (Note 2)
9T
SU:DAT Data Input Setup Time 100 — — ns 2.5V ≤ VCC ≤ 5.5V
250 — — ns 1.7V ≤ V
CC < 2.5V (24AA01)
50 — — ns 1.7V ≤ VCC ≤ 5.5V (24FC01)
10 T
SU:STO Stop Condition Setup
Time
600 — — ns 2.5V ≤ VCC ≤ 5.5V
4000 — — ns 1.7V ≤ V
CC < 2.5V (24AA01)
250 — — ns 1.7V ≤ VCC ≤ 5.5V (24FC01)
11 T
SU:WP WP Setup Time 0 — — ns 1.7V ≤ VCC ≤ 5.5V (24FC01)
12 T
HD:WP WP Hold Time 1000 — — ns 1.7V ≤ VCC ≤ 5.5V (24FC01)
13 TAA Output Valid from Clock — — 900 ns 2.5V ≤ VCC ≤ 5.5V (Note 2)
— — 3500 ns 1.7V ≤ V
CC < 2.5V (24AA01)
(Note 2)
— — 450 ns 1.7V ≤ VCC ≤ 5.5V (24FC01)
(Note 2)
Note 1: Characterized but not 100% tested.
2: As a transmitter, the device must provide an internal minimum delay time to bridge the undefined region
(minimum 300 ns) of the falling edge of SCL to avoid unintended generation of Start or Stop conditions.
3: C
B = total capacitance of one bus line in pF.
4: This parameter is not tested but ensured by characterization. For endurance estimates in a specific
application, please consult the Total Endurance™ Model which can be obtained from Microchip’s website at
www.microchip.com.