User`s guide

MPLAB IDE Dialogs
© 2006 Microchip Technology Inc. DS51519B-page 165
13.6 CONFIGURE CHANNEL DIALOG
Select pin and/or bus signals to be used by the Logic Analyzer window (see
Section 12.18 “Logic Analyzer Window”). Pin signals show changes on individual
pins. Bus signals show changes (in Hex) for multiple pins, as for a port. Each signal
chosen will be given its own channel in the Logic Analyzer display.
To add signals to a channel:
Select the type of signal to add from the pull down list: pin, bus or both. Buses can
be created by clicking Configure Bus(es).
Click on a signal in the “Available Signals” column to select it. To select more than
one signal at a time, use shift-click (for a continuous group) or Ctrl-Click (for a
non-continuous group) to select additional signals.
•Click Add=> to add the signals to the “Selected Signals” column. The signals are
added as one per channel.
To delete signals from a channel:
Click on a signal in the “Selected Signals” column to select it. To select more than
one signal at a time, use shift-click (for a continuous group) or Ctrl-Click (for a
non-continuous group) to select additional signals.
•Click Remove<= to remove the signals to the “Selected Signals” column.
To change the list order of channels:
Click on a signal/channel in “Selected Signals” to select it.
•Use Move Up or Move Down to move the selection in the list.
13.7 CONFIGURE BUS DIALOG
Create/remove buses to be used as channels (see Section 13.6 “Configure Channel
Dialog”) by the Logic Analyzer window (see Section 12.18 “Logic Analyzer Win-
dow”).
To create/remove a bus:
•Click on New Bus to create a new bus. You will be asked to supply a name. The
new bus will appear under “Available Bus(es)”.
Click on a bus under “Available Bus(es)” and then click Delete Bus to remove the
bus from the available list.
To add signals to a bus:
Click on the bus under “Available Bus(es)” to which you want to add signals.
Click on a signal in the “Available Signals” column to select it. To select more than
one signal at a time, use shift-click (for a continuous group) or Ctrl-Click (for a
non-continuous group) to select additional signals.
•Click Add=> to add the signals to the “Selected Signals” column. The signals are
added from the Most Significant bit (MSb) at the top of the list to the Least
Significant bit (LSb) at the bottom of the list.
To delete signals from a channel:
Click on the bus under “Available Bus(es)” from which you want to delete signals.
Click on a signal in the “Selected Signals” column to select it. To select more than
one signal at a time, use shift-click (for a continuous group) or Ctrl-Click (for a
non-continuous group) to select additional signals.
•Click Remove<= to remove the signals to the “Selected Signals” column.
To change the list order of channels:
Click on a signal/channel in “Selected Signals” to select it.
•Use Move Up or Move Down to move the selection in the list.