User`s guide
ZENA™ Wireless Network Analyzer User’s Guide
DS51606C-page 16 © 2008 Microchip Technology Inc.
TABLE 3-3: ZigBee™ PROTOCOL PROFILE/ENDPOINTS CONFIGURATION SELECTION
Configuration Option Description
Profile Header File Click Browse to browse to and select the header file for the application’s profile. This
file has profile information in a specific format which the ZENA™ analyzer uses to
configure many items, including:
- Profile name
- The list of devices supported by the profile
- Allowable input and output clusters
- Range checking for various parameters on other tabs
Device
(1)
Select the profile device that describes the application.
Endpoints
(2)
To define an endpoint:
1. Enter the endpoint’s numerical value (1-240) in the “Endpoint” edit box.
2. In the “Endpoint Name” edit box, enter a valid C language label for that end-
point.
3. Select all of the input and output clusters that are supported by that endpoint
under “Input Clusters” and “Output Clusters”.
4. Click Save Endpoint to save the endpoint. The endpoint number will be added
to the “Endpoints” list box.
To define another endpoint:
1. Click New in the “Endpoints” list box. All of the endpoint information will be
cleared.
2. Enter the new endpoint’s information and click Save Endpoint.
To view a previously defined endpoint:
Click on the endpoint number in the “Endpoints” list box.
To remove a specified endpoint:
Click the desired endpoint number in the “Endpoints” list box and click Remove
Endpoint.
Note 1: The ZENA analyzer does not confirm that all mandatory clusters are supported for the selected device.
2: Be sure to click Save Endpoint when you are finished defining an endpoint. If the endpoint information
has been entered but not saved, the endpoint will not be included in the generated output files.