Revision 1.0 (07-14-09) 36 SMSC USB3320
DATASHEET
Note: The IdGnd switch has been provided to ground the ID pin for future applications.
5.6.2 VBUS Monitor and Pulsing
The USB3320 includes all of the VBUS comparators required for OTG. The VBUSVld, SessVld, and
SessEnd comparators shown in Figure 5.11 are fully integrated into the USB3320. These comparators
are used to monitor changes in the VBUS voltage, and the state of each comparator can be read from
the USB Interrupt Status register.
The VbusVld comparator is used by the Link, when configured as an A device, to ensure that the
VBUS voltage on the cable is valid. The SessVld comparator is used by the Link when configured as
both an A or B device to indicate a session is requested or valid. Finally the SessEnd comparator is
used by the B-device to indicate a USB session has ended.
Also included in the VBUS Monitor and Pulsing block are the resistors used for VBUS pulsing in SRP.
The resistors used for VBUS pulsing include a pull-down to ground and a pull-up to VDD33.
In some applications, voltages much greater than 5.5V may be present at the VBUS pin of the USB
connector. The USB3320 includes an overvoltage protection circuit that protects the VBUS pin of the
USB3320 from excessive voltages as described in Section 5.6.2.6, and shown in Figure 5.11.
5.6.2.1 SessEnd Comparator
The SessEnd comparator is designed to trip when VBUS is less than 0.5 volts. When VBUS goes
below 0.5 volts the USB session is considered to be ended, and SessEnd will transition from 0 to 1.
The SessEnd comparator can be disabled by clearing this bit in both the USB Interrupt Enable Rising
and USB Interrupt Enable Falling registers. When disabled, the SessEnd bit in the USB Interrupt Status
register will read 0. The SessEnd comparator trip points are detailed in Table 4.7.
Figure 5.11 USB3320 OTG VBUS Block
R
VPD
VbusValid
SessValid
SessEnd
DischrgVbus
0.5V
1.4V
4.575V
VBUS
~
~
~
~
VDD33
SMSC PHY
To USB Con.
SessEnd Rise or
SessEnd Fall
VbusValid Rise or
VbusValid Fall
RXCMD VbusValid
IndicatorComplement
[UseExternalVbusindicator, IndicatorPassThru]
[0, X]
[1, 0]
[1, 1]
EXTVBUS (logic 1)
R
VB
R
VPU
ChrgVbus
VBUS
Overvoltage
Protection
R
VBUS
en
en