Datasheet
Hi-Speed USB Host, Device or OTG PHY with ULPI Low Pin Interface
Datasheet
Revision 1.1 (01-24-13) 28 SMSC USB3300
DATASHEET
6.1.4.8 USB Interrupt Enable Rising: Address = 0D-0Fh (read), 0Dh (write), 0Eh (set), 0Fh
(clear)
6.1.4.9 USB Interrupt Enable Falling: Address = 10-12h (read), 10h (write), 11h (set), 12h
(clear)
DrvVbus 5 0b Used to enable external 5 volt supply to drive 5 volts on VBUS.
This signal is or’ed with DrvVbusExternal.
0b: do not drive VBUS
1b: drive VBUS
DrvVbusExternal 6 0b Used to enable external 5 volt supply to drive 5 volts on VBUS.
This signal is or’ed with DrvVbus.
0b: do not drive VBUS
1b: drive VBUS
UseExternalVbus
Indicator
7 0b Tells the PHY to use an external VBUS over-current or voltage
indicator. This function is detailed in Section 6.5.4, "External
Vbus Indicator".
0b: Use the internal VbusValid comparator
1b: Use the EXTVBUS input as for VbusValid signal.
FIELD NAME BIT DEFAULT DESCRIPTION
HostDisconnect Rise 0 1b Generate an interrupt event notification when Hostdisconnect
changes from low to high. Applicable only in host mode.
VbusValid Rise 1 1b Generate an interrupt event notification when Vbusvalid changes
from low to high.
SessValid Rise 2 1b Generate an interrupt event notification when SessValid changes
from low to high.
SessEnd Rise 3 1b Generate an interrupt event notification when SessEnd changes
from low to high.
IdGnd Rise 4 1b Generate an interrupt event notification when IdGnd changes
from low to high.
Reserved 7:5 0h Driven low.
FIELD NAME BIT DEFAULT DESCRIPTION
HostDisconnect Fall 0 1b Generate an interrupt event notification when Hostdisconnect
changes from high to low. Applicable only in host mode.
VbusValid Fall 1 1b Generate an interrupt event notification when Vbusvalid changes
from high to low.
SessValid Fall 2 1b Generate an interrupt event notification when SessValid changes
from high to low.
FIELD NAME BIT DEFAULT DESCRIPTION