Datasheet
Table Of Contents
- Chapter 1 USB251x Hub Family Differences Overview
- Chapter 2 General Description
- Chapter 3 Acronyms
- Chapter 4 Block Diagram
- Chapter 5 Pin Descriptions
- Chapter 6 LED Usage Description
- Chapter 7 Battery Charging Support
- Chapter 8 Configuration Options
- Chapter 9 DC Parameters
- 9.1 Maximum Guaranteed Ratings
- 9.2 Operating Conditions
- Figure 9.1 Supply Rise Time Model
- Table 9.1 DC Electrical Characteristics (continued)
- Table 9.2 Supply Current Unconfigured: Hi-Speed Host (ICCINTHS)
- Table 9.3 Supply Current Unconfigured: Full-Speed Host (ICCINTFS)
- Table 9.4 Supply Current Configured: Hi-Speed Host (IHCH1)
- Table 9.5 Supply Current Configured: Full-Speed Host (IFCC1)
- Table 9.6 USB251x/xi/xA/xAi Supply Current Suspend (ICSBY)
- Table 9.7 USB251xB/xBi Supply Current Suspend (ICSBY)
- Table 9.8 USB251x/xi/xA/xAi Supply Current Reset (ICRST)
- Table 9.9 USB251xB/xBi Supply Current Reset (ICRST)
- Table 9.10 Pin Capacitance for USB251x, USB251xi, USB251xA, USB251xAi
- Table 9.11 Pin Capacitance for USB251xB and USB251xBi
- 9.2.1 Package Thermal Specifications
- Chapter 10 AC Specifications
- Chapter 11 Package Outlines

USB 2.0 Hi-Speed Hub Controller
Datasheet
SMSC USB251x 41 Revision 1.1 (04-26-10)
DATASHEET
8.2.1.11 Register 0Ah: Port Disable For Self-Powered Operation
8.2.1.12 Register 0Bh: Port Disable For Bus-Powered Operation
BIT
NUMBER BIT NAME DESCRIPTION
7:0 PORT_DIS_SP Port Disable Self-Powered: Disables 1 or more ports.
0 = Port is available
1 = Port is disabled
During self-powered operation when mapping mode is disabled
(PRTMAP_EN='0'), this selects the ports which will be permanently disabled,
and are not available to be enabled or enumerated by a host controller. The
ports can be disabled in any order, the internal logic will automatically report
the correct number of enabled ports to the USB host, and will reorder the
active ports in order to ensure proper function.
When using the internal default option, the PRT_DIS_P[x:1] and
PRT_DIS_M[x:1] pins will disable the appropriate ports.
Bit 7= Controls Port 7
Bit 6= Controls Port 6
Bit 5= Controls Port 5
Bit 4= Controls Port 4
Bit 3= Controls Port 3
Bit 2= Controls Port 2
Bit 1= Controls Port 1
Bit 0= Reserved, always = ‘0’
BIT
NUMBER BIT NAME DESCRIPTION
7:0 PORT_DIS_BP Port Disable Bus-Powered: Disables 1 or more ports.
0 = Port is available
1 = Port is disabled
During self-powered operation when mapping mode is disabled
(PRTMAP_EN='0'), this selects the ports which will be permanently disabled,
and are not available to be enabled or enumerated by a host Controller. The
ports can be disabled in any order, the internal logic will automatically report
the correct number of enabled ports to the USB host, and will reorder the
active ports in order to ensure proper function.
When using the internal default option, the PRT_DIS_P[x:1] and
PRT_DIS_M[x:1] pins will disable the appropriate ports.
Bit 7= Controls Port 7
Bit 6= Controls Port 6
Bit 5= Controls Port 5
Bit 4= Controls Port 4
Bit 3= Controls Port 3
Bit 2= Controls Port 2
Bit 1= Controls Port 1
Bit 0 is Reserved, always = ‘0’