Datasheet
Table Of Contents
- Chapter 1 USB251x Hub Family Differences Overview
- Chapter 2 General Description
- Chapter 3 Acronyms
- Chapter 4 Block Diagram
- Chapter 5 Pin Descriptions
- Chapter 6 LED Usage Description
- Chapter 7 Battery Charging Support
- Chapter 8 Configuration Options
- Chapter 9 DC Parameters
- 9.1 Maximum Guaranteed Ratings
- 9.2 Operating Conditions
- Figure 9.1 Supply Rise Time Model
- Table 9.1 DC Electrical Characteristics (continued)
- Table 9.2 Supply Current Unconfigured: Hi-Speed Host (ICCINTHS)
- Table 9.3 Supply Current Unconfigured: Full-Speed Host (ICCINTFS)
- Table 9.4 Supply Current Configured: Hi-Speed Host (IHCH1)
- Table 9.5 Supply Current Configured: Full-Speed Host (IFCC1)
- Table 9.6 USB251x/xi/xA/xAi Supply Current Suspend (ICSBY)
- Table 9.7 USB251xB/xBi Supply Current Suspend (ICSBY)
- Table 9.8 USB251x/xi/xA/xAi Supply Current Reset (ICRST)
- Table 9.9 USB251xB/xBi Supply Current Reset (ICRST)
- Table 9.10 Pin Capacitance for USB251x, USB251xi, USB251xA, USB251xAi
- Table 9.11 Pin Capacitance for USB251xB and USB251xBi
- 9.2.1 Package Thermal Specifications
- Chapter 10 AC Specifications
- Chapter 11 Package Outlines

USB 2.0 Hi-Speed Hub Controller
Datasheet
Revision 1.1 (04-26-10) 26 SMSC USB251x
DATASHEET
MISC
XTALIN ICLKx Crystal Input
24 MHz crystal
This pin connects to either one terminal of the crystal or to an external
24 MHz clock when a crystal is not used.
CLKIN External Clock Input
This pin connects to either one terminal of the crystal or to an external
24 MHz clock when a crystal is not used.
XTALOUT OCLKx Crystal Output
24 MHz crystal
This is the other terminal of the crystal, or a no connect pin, when an external
clock source is used to drive XTALIN/CLKIN.
SUSP_IND /
LOCAL_PWR /
NON_REM[0]
I/O Active/Suspend status LED
Suspend Indicator: Indicates USB state of the hub.
‘negated’ = Unconfigured, or configured and in USB Suspend
‘asserted’ = the hub is configured, and is active (i.e., not in suspend)
Local Power: Detects availability of local self-power source.
Low = Self/local power source is NOT available (i.e., the hub gets all power
from Upstream USB VBus).
High = Self/local power source is available.
NON_REM[0] Strap Option:
If this strap is enabled by package and configuration settings (see Table 8.1,
"Hub Configuration Options"), this pin will be sampled (in conjunction with
NON_REM[1]) at RESET_N negation to determine if ports [x:1] contain
permanently attached (non-removable) devices. Also, the active state of the
LED will be determined as follows:
NON_REM[1:0] = ‘00’, All ports are removable, and the LED is active high
NON_REM[1:0] = ‘01’, Port 1 is non-removable, and the LED is active low
NON_REM[1:0] = ‘10’, Ports 1 & 2 are non-removable, and the LED is active
high
NON_REM[1:0] = ‘11’, When available, ports 1, 2 & 3 are non-removable, and
the LED is active low
TEST IPD TEST pin
User must treat as a no connect pin or connect to ground. No trace or signal
should be routed or attached to this pin.
Table 5.2 USB251x Pin Descriptions (continued)
SYMBOL
BUFFER
TYPE DESCRIPTION