Datasheet

2001-2012 Microchip Technology Inc. DS21462D-page 3
TC74
START Condition Setup Time
(for repeated START
Condition)
t
SU(START)
4.0 µsec 90% SCLK to 10% SDA
START Condition Hold Time t
H(START)
4.0 µsec
Data In Setup Time t
SU-DATA
1000 nsec
Data In Hold Time t
H-DAT
1250 nsec
STOP Condition Setup Time t
SU(STOP)
4.0 µsec
Bus Free Time Prior to New
Transition
t
IDLE
4.7 µsec
Power-on Reset Delay t
POR
—500µsecV
DD
V
POR
(Rising Edge)
DC CHARACTERISTICS (CONTINUED)
Electrical Specifications: Unless otherwise noted, V
DD
= 3.3V for TC74AX-3.3VXX and
V
DD
= 5.0V for TC74AX-5.0VXX, -40°C T
A
125°C. Note 5
Parameters Sym Min Typ Max Units Conditions
Note 1: Operating current is an average value integrated over multiple conversion cycles. Transient current may
exceed this specification.
2: Maximum ensured conversion time after Power-on Reset (POR to DATA_RDY) is 250 msec.
3: Output current should be minimized for best temperature accuracy. Power dissipation within the TC74 will
cause self-heating and temperature drift error.
4: SDA and SCLK must be connected to V
DD
or GND.
5: V
DD
= 3.3V for TC74AX -3.3 VXX. V
DD
= 5.0V for TC74AX -5.0 VXX. All part types of the TC74 will operate
properly over the wider power supply range of 2.7V to 5.5V. Each part type is tested and specified for rated
accuracy at its nominal supply voltage. As V
DD
varies from the nominal value, accuracy will degrade 1°C/V
of V
DD
change.