Datasheet
Data Sheet
32 Mbit Multi-Purpose Flash Plus
SST39VF3201B / SST39VF3202B
11
©2009 Silicon Storage Technology, Inc. S71384-01-000 1/09
Power Up Specifications
All functionalities and DC specifications are specified for a V
DD
ramp rate of greater than 1V per 100 ms (0V to 3V
in less than 300 ms). If the VDD ramp rate is slower than 1V per 100 ms, a hardware reset is required. The recom-
mended V
DD
power-up to RESET# high time should be greater than 100 µs to ensure a proper reset.
FIGURE 4: Power-Up Diagram
Absolute Maximum Stress Ratings (Applied conditions greater than those listed under “Absolute Maximum
Stress Ratings” may cause permanent damage to the device. This is a stress rating only and functional operation
of the device at these conditions or conditions greater than those defined in the operational sections of this data
sheet is not implied. Exposure to absolute maximum stress rating conditions may affect device reliability.)
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -65°C to +150°C
D. C. Voltage on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to V
DD
+0.5V
Transient Voltage (<20 ns) on Any Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -2.0V to V
DD
+2.0V
Voltage on A
9
Pin to Ground Potential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.5V to 13.2V
Package Power Dissipation Capability (T
A
= 25°C) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0W
Surface Mount Solder Reflow Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C for 10 seconds
Output Short Circuit Current
1
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 mA
1. Outputs shorted for no more than one second. No more than one output shorted at a time.
Operating Range
Range Ambient Temp V
DD
Commercial
Industrial
0°C to +70°C
-40°C to +85°C
2.7-3.6V
2.7-3.6V
AC Conditions of Test
Input Rise/Fall Time . . . . . . . . . . . . . . 5 ns
Output Load . . . . . . . . . . . . . . . . . . . . C
L
= 30 pF
See Figures 19 and 20
1384 F24.0
V
DD
RESET#
CE#
T
PU-READ
> 100 µs
V
DD
min
0V
V
IH
T
RHR
> 50ns