Datasheet

©2011 Silicon Storage Technology, Inc. DS25001A 03/11
15
2 Mbit / 4 Mbit / 8 Mbit Multi-Purpose Flash
SST39LF200A / SST39LF400A / SST39LF800A
SST39VF200A / SST39VF400A / SST39VF800A
Data Sheet
A
Microchip Technology Company
Table 11: DC Operating Characteristics –V
DD
= 3.0-3.6V for SST39LF200A/400A/800A and
2.7-3.6V for SST39VF200A/400A/800A
1
Symbol Parameter
Limits
Test ConditionsMin Max Units
I
DD
Power Supply Current Address input=V
ILT
/V
IHT,
at f=1/T
RC
Min, V
DD
=V
DD
Max
Read
2
30 mA CE#=V
IL
, OE#=WE#=V
IH
, all I/Os
open
Program and Erase 30 mA CE#=WE#=V
IL
, OE#=V
IH
I
SB
Standby V
DD
Current 20 µA CE#=V
IHC
,V
DD
=V
DD
Max
I
LI
Input Leakage Current 1 µA V
IN
=GND to V
DD
,V
DD
=V
DD
Max
I
LO
Output Leakage Current 10 µA V
OUT
=GND to V
DD
,V
DD
=V
DD
Max
V
IL
Input Low Voltage 0.8 V
DD
=V
DD
Min
V
IH
Input High Voltage 0.7V
DD
VV
DD
=V
DD
Max
V
IHC
Input High Voltage (CMOS) V
DD
-0.3 V V
DD
=V
DD
Max
V
OL
Output Low Voltage 0.2 V I
OL
=100 µA, V
DD
=V
DD
Min
V
OH
Output High Voltage V
DD
-0.2 V I
OH
=-100 µA, V
DD
=V
DD
Min
T11.7 25001
1. Typical conditions for the Active Current shown on page 1 are average values at 25°C (room temperature),
and V
DD
= 3V for VF devices. Not 100% tested.
2. Values are for 70 ns conditions. See the Multi-Purpose Flash Power Rating application note for further information.
Table 12: Recommended System Power-up Timings
Symbol Parameter Minimum Units
T
PU-READ
1
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
Power-up to Read Operation 100 µs
T
PU-WRITE
1
Power-up to Program/Erase Operation 100 µs
T12.0 25001
Table 13: Capacitance (T
A
= 25°C, f=1 Mhz, other pins open)
Parameter Description Test Condition Maximum
C
I/O
1
1. This parameter is measured only for initial qualification and after a design or process change that could affect this parameter.
I/O Pin Capacitance V
I/O
=0V 12pF
C
IN
1
Input Capacitance V
IN
=0V 6pF
T13.0 25001
Table 14: Reliability Characteristics
Symbol Parameter Minimum Specification Units Test Method
N
END
1,2
1. This parameter is measured only for initial qualification and after a design or process change that could affect this
parameter.
2. N
END
endurance rating is qualified as a 10,000 cycle minimum for the whole device. A sector- or block-level rating would
result in a higher minimum specification.
Endurance 10,000 Cycles JEDEC Standard A117
T
DR
1
Data Retention 100 Years JEDEC Standard A103
I
LTH
1
Latch Up 100 + I
DD
mA JEDEC Standard 78
T14.2 25001