User's Manual
Roving Networks Wifly RN-111B User Guide Version 1.16
www.rovingnetworks.com
support@rovingnetworks.com
Phone 408-395-6539
- 23 -
6. Factory Default Power up Settings
Note: PIO(9) IF pulled HIGH (3.3V) at power up time, and then toggled 3 times will
change all settings below back to their factory values.
COMM PARAMETERS
Close string CLOSE
Open string OPEN
Remote string Hello
FlushSize 32
MatchByte 13 ( = ‘\r’)
FlushTimer 0
IdleTimer 0
IP PARAMETERS
protocol TCP-Server
address 0.0.0.0
localport 2000
netmask 0.0.0.0
gateway 0.0.0.0
host 0.0.0.0
remoteport 2000
ftp 64.62.207.72 (rovingnetworks.com ) (port fixed at 21)
dhcp 1 (enabled)
SYSTEM PARAMETERS
sleeptimer 0
waketimer 10 (10 seconds after sleep we wake up)
trigger 1 (SENS1 pin wakes up the device)
auto connect 0
iomask 0x78 ( 3,4,5,6 outputs ).
print level 1 (startup prints enabled)
TIME SERVER PARAMETERS
enable 0= disabled
address 158.152.1.76
port 37
UART PARAMETERS
Baudrate 115200
parity n (none)
flow 0=disabled
WLAN PARAMETERS
authentication 0=disabled
channel 1
ssid Linksys
rate 1 (1= 1Mbit)