Datasheet
2009-2013 Microchip Technology Inc. DS60001156H-page 383
PIC32MX5XX/6XX/7XX
FIGURE 31-9: OCx/PWM MODULE TIMING CHARACTERISTICS
OCFA/OCFB
OCx
OC20
OC15
Note: Refer to Figure 31-1 for load conditions.
OCx is tri-stated
TABLE 31-27: SIMPLE OCx/PWM MODE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.3V to 3.6V
(unless otherwise stated)
Operating temperature -40°C T
A +85°C for Industrial
-40°C TA +105°C for V-Temp
Param
No.
Symbol Characteristics
(1)
Min Typical
(2)
Max Units Conditions
OC15 TFD Fault Input to PWM I/O Change — — 50 ns —
OC20 TFLT Fault Input Pulse Width 50 — — ns —
Note 1: These parameters are characterized, but not tested in manufacturing.
2: Data in “Typical” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only
and are not tested.