Datasheet
PIC32MX5XX/6XX/7XX
DS60001156H-page 326 2009-2013 Microchip Technology Inc.
REGISTER 24-36: EMAC1MIND: ETHERNET CONTROLLER MAC MII MANAGEMENT INDICATORS
REGISTER
Bit
Range
Bit
31/23/15/7
Bit
30/22/14/6
Bit
29/21/13/5
Bit
28/20/12/4
Bit
27/19/11/3
Bit
26/18/10/2
Bit
25/17/9/1
Bit
24/16/8/0
31:24
U-0 U-0 U-0 U-0 U-0 U-0 U-0 U-0
— — — — — — — —
23:16
U-0 U-0 U-0 U-0 U-0 U-0 U-0 U-0
— — — — — — — —
15:8
U-0 U-0 U-0 U-0 U-0 U-0 U-0 U-0
— — — — — — — —
7:0
U-0 U-0 U-0 U-0 R/W-0 R/W-0 R/W-0 R/W-0
— — — — LINKFAIL NOTVALID SCAN MIIMBUSY
Legend:
R = Readable bit W = Writable bit U = Unimplemented bit, read as ‘0’
-n = Value at POR ‘1’ = Bit is set ‘0’ = Bit is cleared x = Bit is unknown
bit 31-4 Unimplemented: Read as ‘0’
bit 3 LINKFAIL: Link Fail bit
When ‘1’ is returned - indicates link fail has occurred. This bit reflects the value last read from the PHY status
register.
bit 2 NOTVALID: MII Management Read Data Not Valid bit
When ‘1’ is returned - indicates an MII management read cycle has not completed and the Read Data is not
yet valid.
bit 1 SCAN: MII Management Scanning bit
When ‘1’ is returned - indicates a scan operation (continuous MII Management Read cycles) is in progress.
bit 0 MIIMBUSY: MII Management Busy bit
When ‘1’ is returned - indicates MII Management module is currently performing an MII Management Read
or Write cycle.
Note: Both 16-bit and 32-bit accesses are allowed to these registers (including the SET, CLR and INV registers).
8-bit accesses are not allowed and are ignored by the hardware.